鞍钢鲅鱼圈能源管控系统后端代码
潘志宝
3 天以前 f5982398a509ecfa15fc210f50040511fd1d382b
ansteel-biz/db/mysql.sql
@@ -247,6 +247,9 @@
ALTER TABLE `t_power_net_factor`
    ADD COLUMN `cur_flag` int DEFAULT 0 COMMENT '无功返送(1:大于0是,-1:小于0是)';
ALTER TABLE `t_power_net_factor`
    ADD COLUMN `node_code`  varchar(50) NULL DEFAULT NULL COMMENT '节点编号';
-- ----------------------------
-- 电力功率因数-发电机组实时状态
-- ----------------------------
@@ -351,11 +354,13 @@
    `id`        varchar(36) NOT NULL COMMENT 'id',
    `clock`     varchar(20) NULL DEFAULT NULL COMMENT '查询时间',
    `info_type` varchar(10) NULL DEFAULT NULL COMMENT '信息类型(0:生产情况,1:能源发生,2:能源消耗)',
    `ind_code`  varchar(50) NULL DEFAULT NULL COMMENT '数据编码',
    `ind_name`  varchar(50) NULL DEFAULT NULL COMMENT '数据名称',
    `ind_unit`  varchar(50) NULL DEFAULT NULL COMMENT '数据单位',
    `ind_value` varchar(50) NULL DEFAULT NULL COMMENT '数据值',
    `sort`      int NULL DEFAULT NULL COMMENT '排序',
    PRIMARY KEY (`id`) USING BTREE
    PRIMARY KEY (`id`) USING BTREE,
    key         idx_clock (clock)
) ENGINE = InnoDB CHARACTER SET = utf8mb4 COLLATE = utf8mb4_general_ci ROW_FORMAT = DYNAMIC COMMENT '焦化工序日生产信息';
-- ----------------------------
@@ -550,12 +555,17 @@
(
    `id`         varchar(36) NOT NULL COMMENT 'id',
    `rel_id`     varchar(36) NULL DEFAULT NULL COMMENT '关联ID',
    `process`     varchar(20) NULL DEFAULT NULL COMMENT '工序名称',
    `ex_obj`     varchar(20) NULL DEFAULT NULL COMMENT '异常对象',
    `clock`       varchar(20) NULL DEFAULT NULL COMMENT '查询时间',
    `data_type`  varchar(20) NULL DEFAULT NULL COMMENT '数据类型',
    `point_no`   varchar(20) NULL DEFAULT NULL COMMENT '异常点位编号',
    `point_name` varchar(20) NULL DEFAULT NULL COMMENT '异常点位名称',
    `ex_date`    datetime NULL DEFAULT NULL COMMENT '异常时间',
    `ex_type`    varchar(20) NULL DEFAULT NULL COMMENT '异常原因',
    PRIMARY KEY (`id`) USING BTREE
    `ex_time`    datetime NULL DEFAULT NULL COMMENT '异常时间',
    `ex_type`    varchar(200) NULL DEFAULT NULL COMMENT '异常原因',
    `create_date` datetime COMMENT '创建时间',
    PRIMARY KEY (`id`) USING BTREE,
    key           idx_rel_id (rel_id)
) ENGINE = InnoDB CHARACTER SET = utf8mb4 COLLATE = utf8mb4_general_ci ROW_FORMAT = DYNAMIC COMMENT '焦化工序数据异常';
-- ----------------------------
@@ -569,11 +579,15 @@
                                     `sub_process_type` varchar(20) COLLATE utf8mb4_general_ci DEFAULT NULL COMMENT '子工序类型',
                                     `clock` varchar(20) COLLATE utf8mb4_general_ci DEFAULT NULL COMMENT '查询时间',
                                     `steam_p` decimal(10,4) DEFAULT NULL COMMENT '蒸汽发生',
                                     `dj_steam_p` decimal(10,4) DEFAULT NULL COMMENT '吨焦产蒸汽',
                                     `steam_c` decimal(10,4) DEFAULT NULL COMMENT '蒸汽消耗',
                                     `steam_only_c` decimal(10,4) DEFAULT NULL COMMENT '蒸汽单耗',
                                     `steam_v` decimal(10,4) DEFAULT NULL COMMENT '蒸汽量',
                                     `gas_p` decimal(10,4) DEFAULT NULL COMMENT '煤气发生',
                                     `gas_c` decimal(10,4) DEFAULT NULL COMMENT '煤气消耗',
                                     `power_c` decimal(10,4) DEFAULT NULL COMMENT '电力消耗',
                                     `power_only_c` decimal(10,4) DEFAULT NULL COMMENT '电力单耗',
                                     `power_c_standard` decimal(10,4) DEFAULT NULL COMMENT '电耗基准',
                                     `idle_time` decimal(10,4) DEFAULT NULL COMMENT '空转时间',
                                     `bfg_c` decimal(10,4) DEFAULT NULL COMMENT 'BFG消耗',
                                     `cog_p` decimal(10,4) DEFAULT NULL COMMENT 'COG回收',
@@ -621,13 +635,20 @@
    `sort`         varchar(50)                                                  DEFAULT NULL COMMENT '排序',
    PRIMARY KEY (`id`)
) ENGINE=InnoDB DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci COMMENT='月最大需量,实测需量,有功功率';
ALTER TABLE `t_power_demand`
    ADD COLUMN `code`  varchar(50) NULL DEFAULT NULL COMMENT '编号';
-- ----------------------------
-- 负荷移植-调整后的功率因数与无功倒送量
-- ----------------------------
CREATE TABLE `t_power_adjusted_factor` (
                                           `id` varchar(36) NOT NULL,
                                           `code` varchar(50) DEFAULT NULL COMMENT '编码',
                                           `name` varchar(50) DEFAULT NULL COMMENT '名称',
                                           `pointNo` varchar(50) DEFAULT NULL COMMENT '点位',
                                           `data_type`  varchar(20) NULL DEFAULT NULL COMMENT '数据类型',
                                           `point_no` varchar(50) DEFAULT NULL COMMENT '点位',
                                           `sort` varchar(50) DEFAULT NULL COMMENT '排序',
                                           PRIMARY KEY (`id`)
) ENGINE=InnoDB DEFAULT CHARSET=utf8mb4 COLLATE=utf8mb4_0900_ai_ci COMMENT='调整后的功率因数与无功倒送量';